http://repository.iitr.ac.in/handle/123456789/16275
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Iyer B. | - |
dc.contributor.author | Garg M. | - |
dc.contributor.author | Pathak, Nagendra Prasad | - |
dc.contributor.author | Ghosh, Debashish | - |
dc.date.accessioned | 2020-12-02T14:15:57Z | - |
dc.date.available | 2020-12-02T14:15:57Z | - |
dc.date.issued | 2013 | - |
dc.identifier.citation | Proceedings of Procedia Engineering, (2013), 185- 194. Chennai | - |
dc.identifier.issn | 18777058 | - |
dc.identifier.uri | https://doi.org/10.1016/j.proeng.2013.09.090 | - |
dc.identifier.uri | http://repository.iitr.ac.in/handle/123456789/16275 | - |
dc.description.abstract | This article illustrates application of a concurrent dual-band RF system and Wavelet Transform for contactless detection and analysis of human vital signs (i.e. Heartbeats and Respiration rate) for the first time. The vital signs are captured by a concurrent dual-band measurement setup operating at 2.4/5.2GHz band. An algorithm using Fourier transform and Wavelet transform is used to notice the vital signs from the phase information signal of the concurrent dual-band RF system. The analysis shows that Wavelet transform gives better prediction of vital sign as compared to Fourier transform. The concurrent dual-band operation yields the advantage of measurement of vital sign signals without a change in measurement conditions at both bands. Simulations are carried out using measured dual-band subsystems in ADS platform. In the experimental setup, signals are measured with a human subject at a distance of 1-m away from the RF transceiver. © 2013 The Authors. Published by Elsevier Ltd. | - |
dc.language.iso | en_US | - |
dc.publisher | Elsevier Ltd | - |
dc.relation.ispartof | Proceedings of Procedia Engineering | - |
dc.subject | Concurrent | - |
dc.subject | Contactless | - |
dc.subject | Dual-band | - |
dc.subject | Fourier Transfom | - |
dc.subject | Heartbeats | - |
dc.subject | Respiration rate | - |
dc.subject | RF System | - |
dc.subject | Vital sign | - |
dc.subject | Wavelet transform | - |
dc.title | Contactless detection and analysis of human vital signs using concurrent dual-band RF system | - |
dc.type | Conference Paper | - |
dc.scopusid | 55823712100 | - |
dc.scopusid | 57192181720 | - |
dc.scopusid | 7005642176 | - |
dc.scopusid | 9332444600 | - |
dc.affiliation | Iyer, B., Radio Frequency Integrated Circuit (RFIC) Research Group, Department of Electronics and Communication Engineering, Indian Institute of Technology, Roorkee-247667, Uttarakhand, India | - |
dc.affiliation | Garg, M., Radio Frequency Integrated Circuit (RFIC) Research Group, Department of Electronics and Communication Engineering, Indian Institute of Technology, Roorkee-247667, Uttarakhand, India | - |
dc.affiliation | Pathak, N.P., Radio Frequency Integrated Circuit (RFIC) Research Group, Department of Electronics and Communication Engineering, Indian Institute of Technology, Roorkee-247667, Uttarakhand, India | - |
dc.affiliation | Ghosh, D. | - |
dc.description.correspondingauthor | Iyer, B.; Radio Frequency Integrated Circuit (RFIC) Research Group, Department of Electronics and Communication Engineering, Indian Institute of Technology, Roorkee-247667, Uttarakhand, India; email: bijuiyer@gmail.com | - |
dc.identifier.conferencedetails | 2013 International Conference on Design and Manufacturing, IConDM 2013, Chennai, 18-20 July 2013 | - |
Appears in Collections: | Conference Publications [ECE] |
Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.